====== Retinoblastoma-Fresh Tumor Specimen ====== * Use 25 gauge 5/8 inch needle on 5cc syringe. * Pull back with some force, don't put air in the eye * Look for some tissue, if vitreous comes, eye may flatten * Can fill the eye with some saline and 30g if it flattens * Remove tenons over injection site to prevent trapping cells * Wash eye with saline after pulling out tissue * Ensure the tumor cells are in transport media- small white floaters * Place on Path specimen report that eye was punctured for cell culture * See details on [[retinoblastoma_genetic_testing|UIHC Epic Ordering]] {{tag>retinoblastoma}}