kestenbaum_procedure

Kestenbaum Procedure for Nystagmus

Illustrated for a RIGHT face turn (Eyes are in left gaze- you want to move eyes to the right)

TypeDegree Face Turn Left Eye Right Eye
Recess LRResect MRRecess MRResect LR
Classic<207 mm6 mm5 mm8 mm
Parks309 mm8 mm6.5 mm10 mm
Classic +40%4510 mm8.5 mm7 mm11 mm
Classic +60%5011 mm9.5 mm8 mm12.5 mm

Illustrated for a LEFT face turn (Eyes are in right gaze- you want to move eyes to the left)

TypeDegree Face Turn Right Eye Left Eye
Recess LRResect MRRecess MRResect LR
Classic<207 mm6 mm5 mm8 mm
Parks309 mm8 mm6.5 mm10 mm
Classic +40%4510 mm8.5 mm7 mm11 mm
Classic +60%5011 mm9.5 mm8 mm12.5 mm
  • kestenbaum_procedure.txt
  • Last modified: 2023/12/20 17:17
  • by oculoman